2025/07/02 18:09:07.266 | UpdateTextBox
2025/07/02 18:09:07.267 | UpdateParameter
2025/07/02 18:09:07.269 | UpdateParameter
2025/07/02 18:09:07.269 | UpdateParameter
2025/07/02 18:09:07.270 | UpdateParameter
2025/07/02 18:09:07.270 | UpdateParameter
2025/07/02 18:09:07.271 | UpdateParameter
2025/07/02 18:09:07.271 | UpdateParameter
2025/07/02 18:09:07.272 | UpdateParameter
2025/07/02 18:09:07.272 | UpdateParameter
2025/07/02 18:09:07.273 | UpdateParameter
2025/07/02 18:09:07.273 | UpdateParameter
2025/07/02 18:09:07.274 | UpdateParameter
2025/07/02 18:09:07.275 | UpdateParameter
2025/07/02 18:12:33.792 |  health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:12:33.794 | CheckMCInfo ...
2025/07/02 18:12:33.794 | .\ipmiutil.exe health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:12:33.796 | A True, True, False, False
2025/07/02 18:12:33.796 | B True, True, False, False
2025/07/02 18:13:15.282 | Error: Unable to establish IPMI v2 / RMCP+ session
2025/07/02 18:13:15.283 | 
2025/07/02 18:13:15.283 | ipmi_open_lan2 error -1
2025/07/02 18:13:15.284 | ipmiutil health ver 3.18
2025/07/02 18:13:15.285 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:13:15.285 | ipmiutil health, error -1
2025/07/02 18:13:15.285 | 
2025/07/02 18:13:15.286 | 
2025/07/02 18:13:16.290 | Retry... 1
.
2025/07/02 18:13:16.291 | B True, True, False, False
2025/07/02 18:13:57.695 | ipmiutil health ver 3.18
2025/07/02 18:13:57.696 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:13:57.696 | ipmiutil health, error -1
2025/07/02 18:13:57.696 | Error: Unable to establish IPMI v2 / RMCP+ session
2025/07/02 18:13:57.698 | 
2025/07/02 18:13:57.698 | ipmi_open_lan2 error -1
2025/07/02 18:13:57.701 | 
2025/07/02 18:13:57.701 | 
2025/07/02 18:13:58.704 | Retry... 2
.
2025/07/02 18:13:58.705 | CheckMCInfo Out
2025/07/02 18:14:06.574 |  health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:14:06.575 | CheckMCInfo ...
2025/07/02 18:14:06.575 | .\ipmiutil.exe health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:14:06.577 | A True, True, False, False
2025/07/02 18:14:06.577 | B True, True, False, False
2025/07/02 18:14:48.024 | ipmiutil health ver 3.18
2025/07/02 18:14:48.025 | Error: Unable to establish IPMI v2 / RMCP+ session
2025/07/02 18:14:48.026 | 
2025/07/02 18:14:48.026 | ipmi_open_lan2 error -1
2025/07/02 18:14:48.025 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:14:48.027 | ipmiutil health, error -1
2025/07/02 18:14:48.030 | 
2025/07/02 18:14:48.030 | 
2025/07/02 18:14:49.033 | Retry... 1
.
2025/07/02 18:14:49.039 | CheckMCInfo Out
2025/07/02 18:19:44.632 |  health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:44.633 | CheckMCInfo ...
2025/07/02 18:19:44.633 | .\ipmiutil.exe health -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:44.635 | A True, True, False, False
2025/07/02 18:19:44.635 | B True, True, False, False
2025/07/02 18:19:44.771 | ipmiutil health ver 3.18
2025/07/02 18:19:44.772 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:19:44.772 | BMC manufacturer  | 002728 (ITE Tech. Inc.), product | 5792 
2025/07/02 18:19:44.773 | BMC version       | 1.12, IPMI v2.0
2025/07/02 18:19:44.773 | IPMI driver type  | 9        (lan2)
2025/07/02 18:19:44.773 | Power State       | 2a       (unknown)
2025/07/02 18:19:44.773 | get_selftest_status error, ret = c1
2025/07/02 18:19:44.774 | ipmiutil health, Invalid Command
2025/07/02 18:19:44.774 | 
2025/07/02 18:19:44.773 | 
2025/07/02 18:19:44.777 | CheckMCInfo Out
2025/07/02 18:19:47.505 |  sensor -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:47.505 | GetSensorInfo ...
2025/07/02 18:19:47.506 | .\ipmiutil.exe sensor -c -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:47.507 | A True, True, False, False
2025/07/02 18:19:47.507 | B True, True, False, False
2025/07/02 18:19:47.685 | ipmiutil sensor version 3.18
2025/07/02 18:19:47.686 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:19:47.686 | -- BMC version 1.12, IPMI version 2.0 
2025/07/02 18:19:47.686 |  ID  | SDRType | Type            |SNum| Name             |Status| Reading
2025/07/02 18:19:47.687 | 0000 | Full    | Temperature     | 00 | CPU Temp | OK   | 80.000 C
2025/07/02 18:19:47.687 | 0001 | Full    | Temperature     | 01 | PCH Temp | OK   | 60.000 C
2025/07/02 18:19:47.687 | 0002 | Full    | FRU Sensor      | 22 | S0_Duration | OK   | 0.000 sec
2025/07/02 18:19:47.687 | ipmiutil sensor, completed successfully
2025/07/02 18:19:47.688 | 
2025/07/02 18:19:47.688 | 
2025/07/02 18:19:47.691 | GetSensorInfo Out
2025/07/02 18:19:54.578 |  reset -u -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:54.578 | PowerUp ...
2025/07/02 18:19:54.579 | .\ipmiutil.exe reset -u -N 192.168.116.164 -U admin -P ite -F lan2
2025/07/02 18:19:54.579 | A True, True, False, False
2025/07/02 18:19:54.579 | B True, True, False, False
2025/07/02 18:19:54.680 | ipmiutil reset ver 3.18
2025/07/02 18:19:54.680 | Opening lanplus connection to node 192.168.116.164 ...
2025/07/02 18:19:54.681 | -- BMC version 1.12, IPMI version 2.0 
2025/07/02 18:19:54.681 | Power State      = 2a   (unknown)
2025/07/02 18:19:54.681 | ipmiutil reset: powering up ...
2025/07/02 18:19:54.681 | chassis_reset(1) ok
2025/07/02 18:19:54.681 | ipmiutil reset: IPMI_Reset ok
2025/07/02 18:19:54.681 | ipmiutil reset, completed successfully
2025/07/02 18:19:54.682 | 
2025/07/02 18:19:54.682 | 
2025/07/02 18:19:54.685 | PowerUp Out
2025/07/02 18:22:44.419 | Window_Closing (Main)
2025/07/02 18:22:44.426 | Window_Closed (Main)